The paper investigates the effect of hydraulic turbine speed governor parameters on water gates dynamics of the hydraulic turbines. These parameters are water starting time, temporary speed droop, transient time and permanent speed droop. This is done in order to improve the performance of the hydraulic turbine speed governor in power systems and to reduce water gate oscillations. This paper also investigates the application of the conventional and fuzzy logic controller based on the hydraulic turbine speed governor on water gate dynamics. Nonlinear simulations are performed in a 3 machine power system show that influences.
El-Sadek, M. Z., Shabib, G., & M. Soliman, W. (2006). WATER GATE DYNAMICS AS INFLUENCED BY PARAMETERS OF HYDRAULIC TURBINE SPEED GOVERNORS AND CONTROLLERS. JES. Journal of Engineering Sciences, 34(No 5), 1561-1573. doi: 10.21608/jesaun.2006.111074
MLA
M. Z. El-Sadek; Gaber Shabib; Wael M. Soliman. "WATER GATE DYNAMICS AS INFLUENCED BY PARAMETERS OF HYDRAULIC TURBINE SPEED GOVERNORS AND CONTROLLERS", JES. Journal of Engineering Sciences, 34, No 5, 2006, 1561-1573. doi: 10.21608/jesaun.2006.111074
HARVARD
El-Sadek, M. Z., Shabib, G., M. Soliman, W. (2006). 'WATER GATE DYNAMICS AS INFLUENCED BY PARAMETERS OF HYDRAULIC TURBINE SPEED GOVERNORS AND CONTROLLERS', JES. Journal of Engineering Sciences, 34(No 5), pp. 1561-1573. doi: 10.21608/jesaun.2006.111074
VANCOUVER
El-Sadek, M. Z., Shabib, G., M. Soliman, W. WATER GATE DYNAMICS AS INFLUENCED BY PARAMETERS OF HYDRAULIC TURBINE SPEED GOVERNORS AND CONTROLLERS. JES. Journal of Engineering Sciences, 2006; 34(No 5): 1561-1573. doi: 10.21608/jesaun.2006.111074