Bady, M. (2016). APPLICATION OF AGE OF AIR OF INDOOR ENVIRONMENTS AS A PROMISING INDEX TO EVALUATE THE OUTDOOR AIR QUALITY USING CFD SIMULATIONS. JES. Journal of Engineering Sciences, 44(No 3), 272-281. doi: 10.21608/jesaun.2016.117601
M. Bady. "APPLICATION OF AGE OF AIR OF INDOOR ENVIRONMENTS AS A PROMISING INDEX TO EVALUATE THE OUTDOOR AIR QUALITY USING CFD SIMULATIONS". JES. Journal of Engineering Sciences, 44, No 3, 2016, 272-281. doi: 10.21608/jesaun.2016.117601
Bady, M. (2016). 'APPLICATION OF AGE OF AIR OF INDOOR ENVIRONMENTS AS A PROMISING INDEX TO EVALUATE THE OUTDOOR AIR QUALITY USING CFD SIMULATIONS', JES. Journal of Engineering Sciences, 44(No 3), pp. 272-281. doi: 10.21608/jesaun.2016.117601
Bady, M. APPLICATION OF AGE OF AIR OF INDOOR ENVIRONMENTS AS A PROMISING INDEX TO EVALUATE THE OUTDOOR AIR QUALITY USING CFD SIMULATIONS. JES. Journal of Engineering Sciences, 2016; 44(No 3): 272-281. doi: 10.21608/jesaun.2016.117601
APPLICATION OF AGE OF AIR OF INDOOR ENVIRONMENTS AS A PROMISING INDEX TO EVALUATE THE OUTDOOR AIR QUALITY USING CFD SIMULATIONS
Department of Environmental Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City, Alexandria 21934, Egypt
Abstract
In this work, CFD simulations were performed to assess the air quality within urban domains through applying one of the ventilation indices for enclosed domains. The index is the Age of Air (AoA), which represents the time consumed by the applied wind to reach a particular point after it enters the considered study domain. The study presents an example of evaluating the air quality of urban areas in terms of AoA. The estimated values of the index were compared to the values of another index which is the purging flow rate. The results of this work confirm that; AoA index of indoor environments is a promising index for the air quality assessment of urban domains as well.