• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
JES. Journal of Engineering Sciences
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 53 (2025)
Volume Volume 52 (2024)
Volume Volume 51 (2023)
Volume Volume 50 (2022)
Volume Volume 49 (2021)
Volume Volume 48 (2020)
Volume Volume 47 (2019)
Volume Volume 46 (2018)
Volume Volume 45 (2017)
Volume Volume 44 (2016)
Volume Volume 43 (2015)
Volume Volume 42 (2014)
Volume Volume 41 (2013)
Volume Volume 40 (2012)
Volume Volume 39 (2011)
Volume Volume 38 (2010)
Volume Volume 37 (2009)
Issue No 6
Issue No 5
Issue No 4
Issue No 3
Issue No 2
Issue No 1
Volume Volume 36 (2008)
Volume Volume 35 (2007)
Volume Volume 34 (2006)
Nayel, M. (2009). STUDY OF AIR TERMINALS SHIELDING DUE TO LIGHTNING LEADER SLANT. JES. Journal of Engineering Sciences, 37(No 1), 125-134. doi: 10.21608/jesaun.2009.121028
M. Nayel. "STUDY OF AIR TERMINALS SHIELDING DUE TO LIGHTNING LEADER SLANT". JES. Journal of Engineering Sciences, 37, No 1, 2009, 125-134. doi: 10.21608/jesaun.2009.121028
Nayel, M. (2009). 'STUDY OF AIR TERMINALS SHIELDING DUE TO LIGHTNING LEADER SLANT', JES. Journal of Engineering Sciences, 37(No 1), pp. 125-134. doi: 10.21608/jesaun.2009.121028
Nayel, M. STUDY OF AIR TERMINALS SHIELDING DUE TO LIGHTNING LEADER SLANT. JES. Journal of Engineering Sciences, 2009; 37(No 1): 125-134. doi: 10.21608/jesaun.2009.121028

STUDY OF AIR TERMINALS SHIELDING DUE TO LIGHTNING LEADER SLANT

Article 7, Volume 37, No 1, January and February 2009, Page 125-134  XML PDF (482.4 K)
Document Type: Research Paper
DOI: 10.21608/jesaun.2009.121028
View on SCiNiTO View on SCiNiTO
Author
M. Nayel
Assiut University, Egypt
Abstract
This paper studies the effect of the lightning leader slant on the shielding angle of the air terminal. The lightning leader is modeled by using discrete line charges. The Rizk voltage condition is assumed as the upward lightning leader condition which is the lightning stroke condition to the lightning rod. The attractive radius and the shielding angle of the air terminal are calculated for different air terminal heights, different lightning currents and different lightning leader slopes. The calculated results show that the attractive radius of air terminal depends on the rod height, the lightning current and the lightning leader slope. A formula related between the lightning current, the lightning leader slope, the attractive radius and the air terminal height is proposed. The slant of lightning leader decreases the air terminal shielding angle, especially at low lightning current and long air terminal.
Keywords
Lightning; Air Terminal; Attractive Radius; Shielding Angle; Shielding Failure
Main Subjects
Electrical Engineering, Computer Engineering and Electrical power and machines engineering.
Statistics
Article View: 109
PDF Download: 339
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.