• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
JES. Journal of Engineering Sciences
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 53 (2025)
Volume Volume 52 (2024)
Volume Volume 51 (2023)
Volume Volume 50 (2022)
Volume Volume 49 (2021)
Volume Volume 48 (2020)
Volume Volume 47 (2019)
Volume Volume 46 (2018)
Volume Volume 45 (2017)
Volume Volume 44 (2016)
Volume Volume 43 (2015)
Volume Volume 42 (2014)
Volume Volume 41 (2013)
Volume Volume 40 (2012)
Volume Volume 39 (2011)
Issue No 6
Issue No 5
Issue No 4
Issue No 3
Issue No 2
Issue No 1
Volume Volume 38 (2010)
Volume Volume 37 (2009)
Volume Volume 36 (2008)
Volume Volume 35 (2007)
Volume Volume 34 (2006)
Ali, A., Ismail, I., Ahmed, M. (2011). STUDY OF THE PERFORMANCE OF AIR CONDITIONING SYSTEM INCORPORATING CHILLED WATER STORAGE. JES. Journal of Engineering Sciences, 39(No 6), 1343-1360. doi: 10.21608/jesaun.2011.129445
A.S. Ali; I.M. Ismail; M.S. Ahmed. "STUDY OF THE PERFORMANCE OF AIR CONDITIONING SYSTEM INCORPORATING CHILLED WATER STORAGE". JES. Journal of Engineering Sciences, 39, No 6, 2011, 1343-1360. doi: 10.21608/jesaun.2011.129445
Ali, A., Ismail, I., Ahmed, M. (2011). 'STUDY OF THE PERFORMANCE OF AIR CONDITIONING SYSTEM INCORPORATING CHILLED WATER STORAGE', JES. Journal of Engineering Sciences, 39(No 6), pp. 1343-1360. doi: 10.21608/jesaun.2011.129445
Ali, A., Ismail, I., Ahmed, M. STUDY OF THE PERFORMANCE OF AIR CONDITIONING SYSTEM INCORPORATING CHILLED WATER STORAGE. JES. Journal of Engineering Sciences, 2011; 39(No 6): 1343-1360. doi: 10.21608/jesaun.2011.129445

STUDY OF THE PERFORMANCE OF AIR CONDITIONING SYSTEM INCORPORATING CHILLED WATER STORAGE

Article 7, Volume 39, No 6, November and December 2011, Page 1343-1360  XML PDF (229.57 K)
Document Type: Research Paper
DOI: 10.21608/jesaun.2011.129445
View on SCiNiTO View on SCiNiTO
Authors
A.S. Ali1; I.M. Ismail2; M.S. Ahmed3
1Grad. Student, Mech. Engineering Dept., Faculty of Engineering, Assiut University, Assiut, Egypt
2Professor, Mech. Engineering Dept., Faculty of Engineering, Assiut University, Assiut, Egypt.
3Ph.D., Mech. Engineering Dept., Faculty of Industrial Edu., Sohag University, Sohag, Egypt.
Abstract
In the present study, an air conditioning system with a storage tank was constructed and tested. Along the 24 hrs, eight tank-charge cycles were performed to evaluate the effect of variation local ambient temperature on the system performance. A significant variation in the values of COP due to variation in local ambient temperature in Sohag city was recorded. There are two modes of chilled water storage, full-storage and partialstorage. This study deals with partial-storage mode. In this study, a comparison has been carried out between air conditioning system without chilled water storage and that with storage. Configuration of storage tank has a significant effect on system performance. Two storage tanks with aspect ratio of 1.1 and 2.2 were tested. A COP of 1.63 was achieved for the adopted system for no-storage mode. In partial-storage mode, the COP achieved was 1.73 in case of storage tank with aspect ratio 1.1, and 1.79 with aspect ratio 2.2.